Skip to main content

Overview

This page explains what Oxygen computes, and why it is done this way rather than the obvious way. Each section starts in plain words. The formulas sit in folded sections for readers who want them, and nothing else on the page depends on them.

The core idea: compare changes, not levels

Treated and control units are rarely the same size. A big store sells more than a small one whether or not it ran a promo. So comparing their sales directly says little. Instead, Oxygen asks how much each unit changed:
  1. For each unit, take its average outcome per day before the switch and after it (leaving out the anticipation buffer and washout).
  2. Subtract: that unit’s change is after − before. Each unit is now one number.
  3. Compare the average change of the treated units with the average change of the control units. The difference is the effect.
Anything that hit every unit in the after window, such as a holiday, the weather or a price rise across the chain, shows up in both groups’ changes and cancels out. What is left is what the change added. This is called a difference in differences.
Dot plot of each shopper's change in average order value. The 24 never-switched shoppers scatter around zero with an average of −0.8. Seven of the 8 wave-1 shoppers sit between +17 and +36 and one sits at −52, average +15.4. The gap of +16.3 is marked as the effect.

The staggered promo's first wave, one dot per shopper. The never-switched shoppers changed by −$0.80 on average, the wave-1 shoppers by +$15.40. The effect is the gap, +$16.30. Notice the spread: one treated shopper fell by $52, which is why the result comes with a range.

Why one number per unit matters

A store’s sales on Tuesday look a lot like its sales on Monday. If you analysed every store-day as a separate observation, the analysis would treat 56 days of one store as 56 independent pieces of evidence, when in reality they are closer to one. It would then be far too confident, and declare “significant” results routinely where there is nothing. Collapsing each unit to one number avoids this entirely. The evidence is counted in units, not days. That is also why a chain of 6 stores has an effective sample of 6 however long it runs, and why the time to find that out is at pricing, not after the run.
For unit i, with the outcome averaged over the retained days of each window:
The two groups are compared with Welch’s t-test, which allows the groups to have different sizes and different spreads. The interval is estimate ± t_crit · se, where t_crit uses Welch–Satterthwaite degrees of freedom and the registered significance level, corrected for the number of outcomes registered together (Šidák: 1 − (1 − α)^(1/k) per outcome). With one registered outcome there is no correction at all, which is the reward for writing the plan down first. Units are matched to groups by name, never by position, so the groups can never be silently swapped.With design.one_date_test: permutation a one-date design is instead tested like staggered waves (below), as a single wave: for a handful of treated units beside many controls, where Welch’s degrees of freedom come from the treated units alone.Blocks and matched pairs shape the draw on this path: they make a lopsided split impossible. The analysis then compares the two groups as wholes. Under blocked assignment that comparison is still unbiased, and its uncertainty is, if anything, on the cautious side, so the benefit of blocking shows up as the disastrous draws removed rather than as a narrower interval.

Staggered rollouts: each wave against units still waiting

With several waves, each wave is analysed on its own windows, against only the units that are still untouched for the whole of that wave’s after window: units that never switch, plus units whose own switch (and anticipation buffer) comes after it. The wave results are then averaged, weighted by how many units each wave has. The obvious alternative, one big regression over everyone with an “already switched” flag, quietly uses units that switched earlier as controls for later waves. When the effect differs between waves, that can give some units negative weight and even flip the sign of the answer. Estimating wave by wave against clean controls avoids the problem by construction.

How the staggered result is tested

Waves share control units, so their results are not independent, and there is no honest textbook formula for the uncertainty. Instead Oxygen uses a randomisation test, which asks the question directly:
If the change did nothing, and we had shuffled which units went in which wave, how often would we see a result at least this large?
It reshuffles the units across the actual wave structure, keeping the calendar fixed and staying within blocks, and recomputes the result each time. If the real result is more extreme than almost all shuffles, it is significant. Because this mirrors exactly how the units were assigned, it needs no assumptions about the shape of the data. Each result is first divided by its own uncertainty, worked out the way Welch’s test does it, before it is compared with the shuffles. Without that step the test is fooled when the changed units are naturally noisier than the rest, say a promotion on the busiest products, or when the effect differs a lot from unit to unit and the groups are of unequal size. In those cases it called a change “clear” 30–55% of the time when there was none. With it, that happens about 5% of the time, as the significance level promises.
Histogram of 2,000 reshuffled effects centred on zero, mostly between −12 and +12. A vertical line marks the real result at +12.3. The few bars at least that far from zero on either side are orange; the caption says 51 of 2,000, p about 0.026.

The staggered promo, tested. Grey: the effect the analysis reports for 2,000 random reassignments of which shoppers were in wave 1, wave 2 or neither, as if the promo did nothing. Teal: the real result, +$12.30. Only 51 shuffles (orange) are as far from zero, so p ≈ 0.026.

To test whether the promo could have been worth, say, **$25**, Oxygen subtracts $25 from each treated shopper’s after window, as if the promo had been worth exactly that, and runs the shuffle test again. If the adjusted data now looks like pure noise, $25 stays in the range; if it still looks extreme (now in the negative direction), $25 is ruled out. Searching up and down this way gives the staggered promo’s range: $1.80 to $23.30. $25 is just outside it.
A control is clean for wave g when it never switches, or when its own switch − anticipation falls on or after the end of wave g’s after window. A wave with fewer than 2 units, fewer than 2 clean controls, or a window under the coverage floor is dropped and reported.The p-value. Within each block, unit labels are reshuffled across the block’s permutation groups: one group per observed switch day, plus the never-switched pool (a dropped wave keeps its own group). The number of distinct relabellings is the multinomial count over those groups, multiplied across blocks. Up to 20,000 relabellings are enumerated exactly; above that, 2,000 seeded shuffles are drawn and the p-value is (1 + #{|null| ≥ |observed|}) / (1 + B). The decision is p ≤ α.The smallest possible p-value is 1 / (number of relabellings). If that is already above α, no result could ever be significant, and the design is refused at pricing. For example, two units per group gives only 6 relabellings, which can never reach 5%.The interval is built by test inversion: a candidate effect τ is kept if, after removing τ from every treated observation in proportion to how much of its window was treated, the test does not reject. Each end of the interval is found separately by doubling and then bisection; if no candidate is ever rejected on a side, that side is reported as unbounded. The tempting shortcut, estimate ± critical value of the shuffles, is not used: on real effects it comes out about three times too wide.

Switchbacks: a coin per pair

In a switchback, each pair of consecutive periods has one “on” and one “off” half, chosen by a coin. For each period, Oxygen takes the fleet’s average outcome per unit-day over the period’s days after the washout. Each pair gives on − off, and the effect is the average of the pair differences. The test asks: if the change did nothing, and the coins had landed the other way in some pairs, how often would the average be this large? That is a sign-flip test: every combination of flipped pairs is tried.
Bar chart of eight weekly periods of the fleet's average order value in coin-flipped pairs, with pair differences +14.4, +8.4, +12.6 and +10.1.

The switchback example: four pairs, all positive (+14.4, +8.4, +12.6, +10.1), average +$11.40. Of the 16 ways the four coins could have fallen, only 'all on weeks higher' and 'all off weeks higher' are this extreme, so p = 2/16 = 0.125.

With P pairs there are 2^P sign patterns (enumerated exactly up to 20,000, else 2,000 sampled). Because the patterns come in mirror-image couples, the smallest attainable p-value is 2 / 2^P. At α = 0.05 that needs at least 6 pairs (2/64 ≈ 0.031); 5 pairs give 0.0625. At α = 0.2, 4 pairs suffice (0.125). A pair with a period below the coverage floor is dropped. The interval inverts the same test: candidate τ is subtracted from every pair difference and kept while the test does not reject.

Groups of units

When units are grouped, for example by region, each group’s day is the sum of its members’ outcome on that day, and the analysis runs on groups exactly as it would on units. The effect is then per group-day, and the sample size is the number of groups.

Missing days and coverage

A difference in differences compares the same calendar days across units. So a day that is missing for any unit is dropped for all units. Windows are then measured in calendar days, not in surviving rows: a “56-day” window with 14 days missing is not stretched to 70 days to make up the count. If a window’s share of days with data falls below the coverage floor, it is refused rather than quietly shortened, because the measurement would no longer be the one that was planned. At week, month or hour grain everything above holds with “period” in place of “day”: a week missing for any unit is dropped for all, and a window counts calendar weeks. Each period is numbered consecutively, so the analysis is the same at every grain. On a measure that adds up, with data on every day, the effect per unit-week is 7 times the effect per unit-day over the same days.

Compliance: why the effect gets watered down

Every unit is analysed in the group it was assigned to (intention to treat). If the change only landed at some treated units, or leaked to some controls, the measured effect is a blend of units that got the change and units that did not.
With treated compliance c_t and control leakage c_c, the measured effect is roughly (c_t − c_c) × the change’s own effect. So the design’s promise is restated as MDE ÷ (c_t − c_c): at 67% net compliance, a design that could detect 17.5 could only have detected a full-strength effect of about 26.
Ten bars, seven at $15 labelled landed and three at zero labelled missed, with a dashed line at the measured average of about $10.50.

A promo worth $15 that landed at only 7 of 10 shoppers reads about $10.50: the three missed shoppers still count as treated.

The method assumes treated and control units would have moved together without the change. Oxygen tests this on the before window, where nothing had changed: it splits the before window into two halves and runs the same analysis as if the change had happened at the midpoint. A significant fake effect means the groups were already drifting apart. Staggered designs run the check per wave. The check can only find a problem; it cannot prove there is none. A short before window gives it little power, which is one more reason to choose a generous one.
Line chart in which the treated group jumps from about $115 to $170 halfway through the before window, while the control group stays near $75.

The local shock example. The before window's halves (grey, then orange) disagree because the treated shoppers jumped by $70 at the midpoint. The fake effect between the halves is +$55.90, nearly four standard errors: Diverged.

Cannibalisation: why the floor is wide

The neighbouring measure is analysed with the same method. To say how small a loss could have gone unnoticed, Oxygen prices the neighbour’s own detectable effect on history from before the first switch (400 replays), so the change itself cannot inflate it. That is the “not excluded above X” floor.

The slope: outcome per unit of driver

When a driver is set, the experiment measures two effects: on the driver (how far the lever pushed it) and on the outcome. Their ratio is the slope: dollars of outcome per unit of driver.
A naive interval for a ratio breaks down exactly when the denominator is uncertain. Instead, a candidate slope β is kept when the unchanged estimator, run on outcome − β · driver, does not find an effect. The set of kept values is the interval (an Anderson–Rubin set). When the lever barely moved the driver, the set runs to infinity and is reported as unbounded, which is the honest answer. The driver’s own effect is tested at the registered α as a diagnostic; it is not a registered outcome, so it does not change the correction for multiple outcomes.

Totals and projections

The estimate is an unweighted average effect per unit per day. Three ways of adding it up have very different standing: For the projection, Oxygen checks whether unit size predicts the effect. It measures each unit’s size in a window that ends one window-length before the before window, because correlating a unit’s baseline with its own change from that baseline manufactures a negative correlation out of nothing. It then compares the treated units’ size-effect correlation with the control units’ correlation, which carries the same statistical artefact and none of the real effect. Only a significant difference between the two raises the warning. Each unit is counted once, even when it controls for several waves.

What none of this can fix

  • Results at other units. The effect at the treated units need not hold elsewhere.
  • Parallel trends. Checked, never proven.
  • Effects that differ between units. The detectable effect assumes one effect for everyone. When it varies a lot, true power at the promised effect is lower than advertised.
  • Small samples. The sample is the number of units, groups or pairs, not unit-days.

How the method itself is tested

The statistics are calibrated by simulating whole experiments thousands of times: a fresh panel each time, a known effect added to a randomly chosen group, the real entry point run, and the results counted. The tests check the false-alarm rate, the power at the promised detectable effect, and how often the interval contains the true effect, for single-date, staggered and switchback designs, with and without blocks. The tolerances are tight enough to catch a method that promises 80% power and delivers 75%.